Figure 2 Moving the motor unit
8.
Open the chute.
9.
Remove the Feed Guide. (Figure 3)
1.
Remove the screws (2).
2.
Remove the Feed Guide.
Repairs/Adjustments
REP 15.8.1
Figure 3 Removing the Feed Guide
10. Remove the sensor holder. (Figure 4)
1.
Remove the Tapping Screws (2).
2.
Remove the sensor holder.