Xerox WorkCentre 7132 Service Documentation page 842

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

123-328 UI Internal Range RAP
UI software failure and a coordinate value outside the range of the display screen is detected.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2)
Revision
WorkCentre 7132
123-329 UI Coordinates RAP
UI software failure and a coordinate value that cannot be displayed is detected.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2)
January 2007
2-809
Status-indicator-raps
123-328, 123-329