Xerox WorkCentre 7132 Service Documentation page 620

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

041-319 MCU PWB Interlock Fuse F4
Fuse F4 on the MCU PWB has an open circuit failure.
Procedure
Perform the following:
Check the connection of each MCU PWB electrical connector.
If any service was performed immediately before the fuse failure check that no wire dam-
age was caused in the areas that were serviced.
Check the harness wires for damage on BSD's 1.2A, 9.2, 9.4A, 9.5, 9.7, 4.1A.
If no problems are found replace the MCU PWB (PL 11.1).
Revision
WorkCentre 7132
041-320 MCU PWB Interlock Fuse F3
Fuse F3 on the MCU PWB has an open circuit failure.
Procedure
Perform the following:
Check the connection of each MCU PWB electrical connector.
If any service was performed immediately before the fuse failure check that no wire dam-
age was caused in the areas that were serviced.
Check the harness wires for damage on BSD 1.2A, and 9.3.
If no problems are found replace the MCU PWB (PL 11.1).
January 2007
2-587
Status-indicator-raps
041-319, 041-320