077-314 Tray Module Logic RAP
BSD-ON:3.3
There is a Tray Module logic failure.
Procedure
Perform the following
Switch the power off, disconnect and reconnect P/J541 on the Tray Module PWB, then
on the power.
Check the circuits between P/J125 on the MCU PWB and P/J541 (2TM) or P/J541
(TTM) on the Tray Module PWB (Flag 5, Flag 6) for an open circuit or short circuit failure.
Repair as required.
Perform ADJ 9.3.1 Software Loading and Upgrading.
Revision
WorkCentre 7132
077-602 OHP Sensor RAP
BSD-ON:8.7
A description is not available at time of publication
Procedure
A procedure is not available at time of publication.
January 2007
2-685
Status-indicator-raps
077-314, 077-602