116-790 Stapling Canceled RAP
BSD-ON:12.6
When Staple was specified, there were no staples.
Initial Actions
Power Off/On
Procedure
Execute Component Control [012-242 Low Staple Sensor]. Install and remove the Staple Pin
Cartridge. The display changes.
Y
N
Check the Staple Pin Cartridge for failure or foreign substances. There are no foreign
substances and nothing has failed.
Y
N
Repair the failure and remove the foreign substances.
Check the connections of P/J8818 and P/J8852. P/J8818 and
nected correctly.
Y
N
Connect P/J8818 and P/J8852.
Check the wire between J8818 and J8852 for an open circuit or a short circuit (BSD
12.6). The wire between J8818 and J8852 is conducting without an open circuit or a
short circuit.
Y
N
Repair the open circuit or short circuit.
Measure the voltage between the Finisher PWB P/J8852-1 (+) and GND (-) (BSD 12.6
Flag 2). The voltage is approx. +5VDC.
Y
N
Replace the Finisher PWB (PL 17.12).
Measure the voltage between the Finisher PWB P/J8852-4 (+) and GND (-) (BSD 12.6
Flag 3). Install and remove the Staple Pin Cartridge. The voltage changes.
Y
N
Replace the Finisher PWB (PL 17.12).
Replace the Staple Assembly (PL 17.8) If the problem persists, replace the Finisher PWB
(PL 17.12).
Replace the Finisher PWB (PL 17.12) If the problem persists, replace the MCU PWB (PL 11.1).