Xerox WorkCentre 7132 Service Documentation page 874

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

124-333 ASIC RAP
BSD-ON:16.1
A decompression error occurred in an ESS ASIC (Application Specific Integrated Circuit).
Initial Actions
Power Off/On
Procedure
Pull out and insert the DIMM (PL 11.1) Switch on the power. The problem persists.
Y
N
Return to Service Call Procedures.
Check the connection of each ESS PWB connector. The connectors are securely con-
nected.
Y
N
Connect the connectors.
Turn on the power again. The problem persists.
Y
N
Return to Service Call Procedures.
Replace the ESS PWB (PL 11.2)
If the problem persists replace the DDR DIMM (PL 11.2).
Revision
WorkCentre 7132
124-334 Standard Font ROM RAP
BSD-ON:16.1
An error was detected in the standard Built-In Font ROM.
Procedure
Replace the PS DIMM (PL 11.2)
January 2007
2-841
Status-indicator-raps
124-333, 124-334

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents