133-210 Fax Parameter RAP
BSD-ON:17.1
The parameter value is incorrect due to reasons such as excessive length.
The required parameter is not sent.
Procedure
Check the electrical connections on the FCB PWB (PL 11.3)
If the problem persists replace the FCB PWB (PL 11.3).
Revision
WorkCentre 7132
133-211 Fax Parameter Value Invalid RAP
BSD-ON:17.1
A parameter value exceeds the range or the required parameter is not sent.
Procedure
Check the electrical connections on the FCB PWB (PL 11.3)
If the problem persists replace the FCB PWB (PL 11.3).