Xerox WorkCentre 7132 Service Documentation page 1333

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Chain-Link Name
740-018
M/C Type
740-019
Product Type
740-020
Range Over Chain Link
740-021
Range Over Chain Link
740-022
Range Over Chain Link
740-023
Range Over Chain Link
740-024
Range Over Chain Link
740-025
Range Over Chain Link
740-026
Range Over Chain Link
740-027
Range Over Chain Link
740-055
CRUM Mode Information
740-056
CRUM Mode Switch
740-060
CRUM Comm Fail Information
740-061
Status Regi Information
General procedures information
IOT NVM List
Table 1 Chain 740-xxx IOT Manager
Default
Range
Read/Write Description
-
0~255
R
M/C Type
0: 1MFrom/16KEEPROM
1: 2MFrom/64KEEPROM
Set at Power ON and NVM Initialization.
10
0~255
R
Product Identification
MN/MNPL: 0 (unused)
IBG: 10 (fixed)
0
0~255
RW
Memorizes Link (high byte) that was over the range in Reading at Power On.
0
0~255
RW
Memorizes Link (low byte) that was over the range in Reading at Power On.
0
0~255
RW
Memorizes abnormal value of Chain Link that was over the range in Reading at Power
On.
(higher bits in 1-byte data/2-byte data; highest bit in 4-byte data)
0
0~255
RW
Memorizes abnormal value of Chain Link that was over the range in Reading at Power
On.
(lower bits in 2-byte data; middle and higher bits in 4-byte data)
0
0~255
RW
Memorizes abnormal value of Chain Link that was over the range in Reading at Power
On.
(middle and lower bits in 4-byte data)
0
0~255
RW
Memorizes abnormal value of Chain Link that was over the range in Reading at Power
On.
(lowest bit in 4-byte data)
0
0~255
RW
a specified number (n) of Links that were over their ranges in Reading at Power On
0
0~255
RW
the number of Chain Links that were over their ranges in Reading at Power On
0
0~1
R
Stores how to control CRUM:
1: 3rd Party Mode (no communication with CRUM)
any except 1: Xerox Mode (communication with CRUM
0
0~1
RW
Switch to change 3rd Party Mode to Xerox Mode
0: N/A
1: transfer to Xerox Mode
0
0~255
RW
At what command CRUM Comm Fail occurred
0: No occurrence
1: at REQ RX Command
2: at ATTRIB Command
3: at CSPWD Command
4: Normally at Read/Write Command
0
0~255
RW
State of Status Register in the event of a CRUM Comm Fail
The content of Register in the event of a fail is stored.
NOTE:
However, the above is not applicable in the following cases:
Data error internal to FIFO occurs: 0xFF will be stored.
Data Length error occurs: 0xFE will be stored (applicable also when FIFOBL exceeds
35).
January 2007
6-10
Reversion 4.0
WorkCentre 7132