Xerox WorkCentre 7132 Service Documentation page 1388

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Chain-Link Name
752-186
Nominal RADC Target[K]
752-187
RADC Target[Y]
752-188
RADC Target[M]
752-189
RADC Target[C]
752-190
RADC Target[K]
752-195
RADC[Y]
752-196
RADC[M]
752-197
RADC[C]
752-198
RADC[K]
752-203
TRC RADC Target[Y][A]
752-204
TRC RADC Target[Y][B]
752-205
TRC RADC Target[Y][C]
752-206
TRC RADC Target[M][A]
752-207
TRC RADC Target[M][B]
752-208
TRC RADC Target[M][C]
752-209
TRC RADC Target[C][A]
752-210
TRC RADC Target[C][B]
752-211
TRC RADC Target[C][C]
752-212
TRC RADC Target[K][A]
752-213
TRC RADC Target[K][B]
752-214
TRC RADC Target[K][C]
752-215
TRC RADC[Y][A]
752-216
TRC RADC[Y][B]
752-217
TRC RADC[Y][C]
752-218
TRC RADC[M][A]
752-219
TRC RADC[M][B]
752-220
TRC RADC[M][C]
752-221
TRC RADC[C][A]
752-222
TRC RADC[C][B]
752-223
TRC RADC[C][C]
752-224
TRC RADC[K][A]
752-225
TRC RADC[K][B]
752-226
TRC RADC[K][C]
752-253
Nominal TRC RADC Target[Y][B]
752-254
Nominal TRC RADC Target[M][B]
752-255
Nominal TRC RADC Target[C][B]
752-256
Nominal TRC RADC Target[K][B]
752-299
SW DispMode
752-301
Timer Disp time[Y]
752-302
Timer Disp time[M]
752-303
Timer Disp time[C]
Reversion 4.0
WorkCentre 7132
Table 9 Process Control
Default
Range
Description
282
0~1023
RADC target value set up as the center
350
0~1023
RADC target value after various corrections
350
0~1023
RADC target value after various corrections
350
0~1023
RADC target value after various corrections
350
0~1023
RADC target value after various corrections
0
0~1023
RADC value calculated from ADC-related detection values
0
0~1023
RADC value calculated from ADC-related detection values
0
0~1023
RADC value calculated from ADC-related detection values
0
0~1023
RADC value calculated from ADC-related detection values
680
0~1023
Target RADC for tone correction
385
0~1023
Target RADC for tone correction
915
0~1023
Target RADC for tone correction
605
0~1023
Target RADC for tone correction
340
0~1023
Target RADC for tone correction
910
0~1023
Target RADC for tone correction
645
0~1023
Target RADC for tone correction
400
0~1023
Target RADC for tone correction
915
0~1023
Target RADC for tone correction
475
0~1023
Target RADC for tone correction
165
0~1023
Target RADC for tone correction
845
0~1023
Target RADC for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
0
0~1023
RADC value for tone correction
385
0~1023
TRC_RADC target value set up as the center
340
0~1023
TRC_RADC target value set up as the center
400
0~1023
TRC_RADC target value set up as the center
165
0~1023
TRC_RADC target value set up as the center
0
0~2
Switch that selects Disp Mode (0: ADC+ICDCdisp 1: ICDCdisp 2: Timerdisp)
5
0~255
Timer Disp set time (in steps of 10ms)
5
0~255
Timer Disp set time (in steps of 10ms)
5
0~255
Timer Disp set time (in steps of 10ms)
January 2007
6-65
General procedures information
IOT NVM List