UI Diagnostic Mode
Procedure
Access UI Diagnostics by following the procedures below.
Entering UI Diagnostics
1.
At the Control Panel, press and hold the 0 key for 5 seconds, then press the Start button
while still pressing the 0 key.
The CE Mode - Password Entry screen will appear.
2.
Enter the Access Number 6789 and press Confirm.
The colors on the display are reversed to indicate that UI Diagnostics mode is active.
Accessing Diagnostic routines
1.
Press the Log In/Out button on the Control Panel.
2.
Select System Settings.
3.
Select Common Settings.
4.
Select Maintenance/Diagnostics.
5.
The following Diagnostics Routines can be accessed from the UI screen. (Figure 1)
a.
NVM Read/Write
Follow the instructions on the screen. If one or more NVM locations is changed,
the machine will reboot upon exit.
b.
Component Control
c.
Sub System
Initialize Hard Disk
Delete All Data
Software Options
Fax Diagnostics
d.
Print Test Pattern
e.
Initialize NVM
f.
Adjustment/Others
Machine ID/Billing Data
Initialize HFSI Counter
Adjust Toner Density
Tray 5(Bypass) Guide Adjustment (Tray 5=MPT)
Reversion 4.0
WorkCentre 7132
Maintenance / Diagnostics
NVM Read / Write
IO Check
Sub System
Print Test Pattern
Max Setup
Initialize NVM
Adjustment / Others
Faults
Figure 1 Maintenance/Diagnostics
January 2007
6-3
Component Control
Analog Monitor
Initialize Hard Disk
Blank Page Threshold
Value
Procon on/off Print
Software Options
IIT Calibration
Size Detection Auto Adjust
Hard Disk Failure
TRC Adjustment
Prediction Test
Adjust Toner Density
Fax Diagnostics
Delete All Data
IOT
Machine ID / Billing Data
Output Device
Initialize HFSI Counter
IISS
Tray 5(Bypass) Guide
Input Device
Adjustment (Tray 5=MPT)
Sys-System
Measure IBT Belt Speed
Sys-User
General procedures information
UI Diagnostic Mode
j0el6101a