Rep 11.4.1 Lens Kit Assembly - Xerox WorkCentre 7132 Service Documentation

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Figure 10 Removal and replacing the IIT EPROM
2.
To install, carry out the removal steps in reverse order.
3.
Check the software level of the new IIT/IPS PWB to ensure that it is current with the
machine software. If the software level is different, upgrade the software on the PWB.
Repairs/Adjustments
REP 11.3.2, REP 11.4.1

REP 11.4.1 Lens Kit Assembly

Parts List on PL 13.4
Removal
To avoid personal injury or shock, do not perform repair or adjustment with electrical
power applied to the machine.
1.
Remove the Platen Glass. (REP 11.3.1)
2.
Remove the Lens Cover. (Figure 1)
NOTE: Notice that the
cut out on the EPROM
Case should be aligned
1
with the white printed
Loosen the screws (6)
cut out on the board.
3.
Remove the APS Sensor. (Figure 2)
1.
2.
3.
January 2007
4-84
WARNING
Figure 1 Removing Lens Cover
Remove the Screw.
Release the wire harness from the clamp.
Remove the APS Sensor.
2
Remove the cover