116-383 PIT Lib Failure RAP
(1) It was detected that the Image Extension Kit (Ama + toto board) was not installed on the
controller board during job execution.
(2) An Ama + toto board failure was detected during job execution.
(3) An HDD access error was detected during job execution.
* Note that although 016-231 is detected during power ON, this fail is a "job execution detec-
tion" and has a different timing.
Procedure
(1) (2) After turning the power OFF then ON, check the panel top right display to see whether
016-231 has occurred, without this error (= 116-383) occurring.
If 016-231 has occurred, perform the corrective actions for 016-231.
If the error does not occur, proceed to (3) for the HDD access error.
Status-indicator-raps
116-383, 116-385
116-385 IDC Software RAP
An internal shutdown occurred after an IDC (scripting language) processing error.
Initial Actions
Power Off/On
Procedure
Reinstall or replace the DIMM (PL 11.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).
January 2007
2-774
Revision
WorkCentre 7132