Chain-Link Name
760-092
Y16
760-093
Y17
760-094
Y18
760-095
Y-Speed Correction Switch
760-096
Y-Speed Correction Learn Value Use Switch
760-097
Y-speed-offset start timing
760-098
Y-speed-offset value
760-100
K-Speed Two Step Correction Switch
760-101
K-speed Two Step offset value
760-102
K-Two Step-speed-offset start timing
760-103
TR0 seal dirt error counter
760-104
TR0 seal dirt warning counter
760-105
Belt Home Position Too Long Fail threshold
Chain 762-xxx Developer
Chain-Link Name
762-001
BIAS_DC_ON
762-002
BIAS_AC_ON
762-003
BIAS_DC_OFF
762-004
BIAS_AC_OFF
762-005
DEVE_MOT_ON
762-006
DEVE_MOT_OFF
762-007
ROT_MOT_ON
762-008
ROT_MOT_OFF
762-009
ROT_MOT_HL_ON
762-010
ROT_MOT_HL_OFF
762-011
FIRST_ROT_TIME_FC
General procedures information
IOT NVM List
Table 11 Registration Control
Read/
Default
Range
Write
Description
96
0~200
RW
Y16
100
0~200
RW
Y17
55000
0~10000
RW
Y18
0
0
0~1
RW
Y Belt Speed Up Correction Switch
0: On
1: Off
0
0~1
RW
Switch sets whether to use learning result in correcting Y Belt speed to speed it up.
0: Learned value
1: NVM value
22
20~30
RW
Time (100msec)from Belt Home detection that triggers plotting an image in Y to the start of
modulating IBT Belt speed
20302
20274~2
RW
The double of this NVM value shall be an actual division ratio in speed modulation for Y.
0355
0
0~1
RW
2-step speed modulation for K
0: On
1: Off
20235
20139~2
RW
2-step Speed Modulation division ratio for K
0274
2600
2000~37
RW
2-step speed modulation starting point for K
00
[msec]
0
0~255
RW
Logs how many times dirt has been detected on the effective area of TR0 sticker.
0
0~255
RW
Logs how many times dirt on TR0 sticker has been detected.
2354
2337~45
RW
Threshold for detecting Broken Belt Fail
30
Table 12 Deve
Default
Range
Read/Write
67
1~145
RW
67
1~145
RW
67
1~145
RW
67
1~145
RW
200
0~1000
RW
1
1^145
RW
10
0~500
RW
10
0~500
RW
30
0~500
RW
200
0~500
RW
693
0~2000
RW
January 2007
6-70
Description
DC BIAS ON Timing (67 Steps before)
AC BIAS ON Timing (67 Steps before)
DC BIAS OFF Timing (67 Steps after)
AC BIAS OFF Timing (67 Steps after)
DEVE_MOT ON Timing (300ms before image)
DEVE_MOT OFF Timing (1 Step after)
ROTARY MOTOR ON Signal ON timing (10ms before HI/LOW signal)
ROTARY MOTOR ON Signal OFF timing (10ms after HI/LOW signal)
ROTARY HI/LOW Signal ON timing (30ms before DEVE CLK)
ROTARY HI/LOW Signal OFF timing (200ms after DEVE CLK)
the timing of starting rotating Rotary when FC cycles up
(693ms before image)