Xerox WorkCentre 7132 Service Documentation page 1404

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Chain-Link Content
715-022
Lamp Fan Fail Bypass
715-023
Lamp Fan On Time (Low Rotation)
715-024
Lamp Fan Off Time
715-025
FL Timer Set
715-026
Lamp ON Interval
715-027
Lamp ON Time
715-030
IIT Failure Part Diagnosis
715-050
Platen SS Registration Adjustment
715-051
Platen SS Reduce/Enlarge Adjustment
715-052
Platen Glass Type
715-053
Platen PRadjF
715-056
CVT FS Offset Side1-1 (139.7-148)
715-057
CVT FS Offset Rear Side2-1 (139.7~148)
715-058
CVT FS Offset Side1-2 (182-194)
715-059
CVT FS Offset Side2-2 (182-194)
715-060
CVT FS Offset Side1-3 (203.2)
715-061
CVT FS Offset Side2-3 (203.2)
715-062
CVT FS Offset Side1-4 (210)
715-063
CVT FS Offset Side2-4 (210)
715-064
CVT FS Offset Side1-5 (214.9-215.9)
715-065
CVT FS Offset Side2-5 (214.9-215.9)
715-066
CVT FS Offset Side1-6 (254-257)
715-067
CVT FS Offset Side2-6 (254-257)
715-068
CVT FS Offset Side1-7 (266.7-267)
715-069
CVT FS Offset Side2-7 (266.7-267)
715-070
CVT FS Offset Side1-8 (279.4)
715-071
CVT FS Offset Side2-8 (279.4)
715-072
CVT FS Offset Side1-9 (297)
715-073
CVT FS Offset Side2-9 (297)
715-074
CVT FS Offset Side3-1 (139.7-148)
715-075
CVT FS Offset Side4-1 (139.7-148)
715-076
CVT FS Offset Side3-2 (182-194)
Reversion 4.0
WorkCentre 7132
Table 3 IISS
Default
Range
Meaning
1
0~1
Existence or of Lamp Fan Fail Detection
0: Lamp Fan Fail Detection existent
1: Lamp Fan Fail Detection not existent
15
0~60
Lamp Fan On at Low Speed time (in minute)
1
0~60
Lamp Fan Off time (in minute)
0
0~1
0: Standard FL Timer settings (30min rest/0.5sec On), 1: Condensation mode setting (Diag 715-
026, 715-027 timer settings apply)
30
0~60
Interval setting (unit: min)
1
0~60
Lamp ON time setting (unit: sec)
1
0~65535
Writing 1 allows starting diagnostics of a failed IIT part.
Reading this NVM after diagnostics is made on a failed part makes a certain presumed part No.
appear.
If a fail occurs during diagnostics of a failed part, Fail Code associated with the fail is logged in this
NVM and the diagnostics ends.
*Even if 1 is written, 1 is not actually done.
*If any value other than 1 is entered, the value becomes illegal.
100
16~184
Slow Scan Direction Regi Correction Value (0.036mm/increment), Factory Settings
50
44~56
Slow Scan Direction Regi Correction Value (0.1%/increment), Factory Settings
2
0~2
0: Platen model, 1: Belt DADF, 2: CVT, Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (Dot), VLSS=PROMVLSS+(PRadjF-120)x2, Factory Set-
tings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (0.1mm/increment) in CVT. Factory Settings
January 2007
6-81
General procedures information
IIT NVM List

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents