Xerox WorkCentre 7132 Service Documentation page 1394

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Chain-Link Name
762-012
FIRST_ROT_TIME_BW
762-014
ROT_MOT_TIME_END
762-015
Home Back Wait Time
762-016
ROTARY_POSITION
762-017
ESCAPE_INT_TIME
762-022
ESCAPE BIAS DC
762-023
BW_TRICLE_START_WAIT
762-024
BW_TRICLE_WAIT_TIME
762-025
BW_TRICLE_DISP_LIMIT
762-026
BW_TRICLE_DISP_TOTAL
762-027
NVM_HOME_ADJ_Switch
762-028
NVM_HOME_ADJ_PULSE
762-029
NVM_ROTARY_FAIL_LIMIT
762-030
Deve_Bias_DC
762-031
Deve_Bias_AC_F
762-032
Deve_Bias_AC_PP
762-033
Deve_Bias_AC_Duty
762-034
CRUM R/W WAIT TIME 1
762-035
CRUM R/W WAIT TIME 2
762-036
HOME POSITION ANGLE
762-038
CRUM R/W WAIT TIME 5
762-039
BAND_DEVE_ROT_TIME_K
762-040
BAND_DEVE_ROT_TIME_Y
762-041
BAND_DEVE_ROT_TIME_M
762-042
BAND_DEVE_ROT_TIME_C
762-043
BAND Cin
762-044
BAND COVERAGE LIMIT
762-045
BAND LENGTH
762-046
Down Step Timing 1
762-047
Down Step Timing 2
Reversion 4.0
WorkCentre 7132
Table 12 Deve
Default
Range
Read/Write
693
0~2000
RW
10
0~500
RW
500
0~2000
RW
0
0~4
RW
1700
0~3000
RW
100
0~1000
RW
500
0~2000
RW
1000
0~3000
RW
1500
0~5000
RW
0
0~5000
RW
0
0~1
RW
33
0~65
RW
8
0~50
RW
570
0~1000
RW
6250
0~10000
RW
1000
0~2000
RW
65
0~100
RW
10
0~500
RW
10
0~500
RW
35
0~65
RW
30
0~500
RW
0
0~65535
RW
0
0~65535
RW
0
0~65535
RW
0
0~65535
RW
60
0~100
RW
75
0~1000
RW
145
0~1000
RW
247
0~1000
RW
50
0~500
RW
January 2007
6-71
Description
the timing of starting rotating Rotary when BW cycles up
(693ms before image)
the timing of starting rotating Rotary when the M/C cycles down (10ms after the
trail edge of image)
Wait Time between Exchange Position and Back Home
(500ms after the instruction)
0: Home
1: Kex
2: Yex
3: Mex
4: Cex
Rest Time (1700ms) in Kesc
Bias DC Value (100V) for generating band for a color that passes the develop-
ment position
Wait Time before starting the operation of trickling toner (500ms after the trail
edge of image)
Wait Time (1000ms) at the position trickling is done
Total Dispense Time Threshold (15sec: in steps of 10ms) in continuous B/W in
order to do the operation of trickling
Total Dispense Time in continuous B/W in order to do the operation of trickling
during job
0: Adjustment Mode not executed
1: Adjustment Mode executed
HOME SENSOR Installing Position Correction Value (N)
Home Position Fail Occurrence Threshold (F)
Deve Bias DC Value (Default: 600V)
Deve Bias AC Frequency (Default: 6000Hz)
Deve Bias AC Vpeak-peak Value (Default: 1000V)
Deve Bias AC Duty (Default: 65%)
Wait Time (ms) before CRUM R/W
Wait Time (ms) after CRUM R/W
Home Position Angle Preset Value (H)
CRUM R/W Escape Wait Time (ms)
Total Deve Drive Time for band generation K
Total Deve Drive Time for band generation Y
Total Deve Drive Time for band generation M
Total Deve Drive Time for band generation C
Band Cin (Default: 60%)
Threshold for Band Execution Judgment
Band Length Calculation standard value
the timing of starting Step Down in Step Control (layout difference from BCR:
227ms+20ms)
In Step Down in Step Control, Vm 3 hours
General procedures information