Chain-Link Content
711-145
T/A Roll Transport Speed Adjustment (Side1)
Replace All
711-146
T/A Roll Transport Speed Adjustment (Side2)
Replace All
711-150
Loop Amount Adjustment (Side1) (x1 Pulse)
711-151
Loop Amount Adjustment (Side2) (x6 Pulse)
711-152
Simplex Speed Mode Switch
711-158
Position Adjustment for End Position during Invert
(x4 Pulse)
711-164
Slow Scan Original Size Correction Value
711-200
Position Adjustment for Pre Regist End Position
(Original Lead Edge Eject Amount from Regi Roll
in x2 Pulse Increments)
711-201
Position Adjustment for Feed Motor Off Start Posi-
tion (x3 Pulse)
711-202
Position Adjustment for Position to Start Increasing
Speed in Duplex (x5 Pulse)
711-203
Position Adjustment for First-Out Pre Feed Posi-
tion in Duplex (x7 Pulse)
711-204
Position Adjustment for N.R. Solenoid On Position
during Invert Output (x8 Pulse)
711-205
Side2 Feed Motor Reverse Start Time Adjustment
Value (T1 ms)
711-207
Next Feed Start Time Adjustment Value (T3 ms)
711-208
Simplex Next Pre Regist Start Time Adjustment
Value (T4 ms)
711-209
Invert Start Time Adjustment Value (T6 ms)
711-210
N.R. Solenoid On Start Time Adjustment Value
during Invert Output (T7 ms)
711-211
First-Out Original Feed Start Time Adjustment
Value (T8 ms)
711-212
Duplex Next Pre Regist Start Time Adjustment
Value (T9 ms)
711-215
Slow Down Start Time Adjustment Value during
Nudger Lift Down (T11 ms)
711-216
Slow Down Start Time Adjustment Value during
Nudger Lift Up (T12 ms)
711-217
Feed Out Sensor Static Jam Detection Sampling
No. Setting
Reversion 4.0
WorkCentre 7132
Table 2 CVT DADF NVM LIST
Default
Range
1 Count
15
0~50
0.001
0
0~50
0.001
3
0~9
0.6835mm
5
0~14
0.4581mm
0
0~1
-
10
20
0.4581mm
50
0~100
0.1mm
8
0~16
0.6249mm
8
1~15
0.6249mm
10
0~20
0.4581mm
5
0~10
0.6835mm
10
0~20
0.4581mm
4
0~20
4msec
5
2~27
4msec
6
6~25
4msec
5
0~25
4msec
5
0~15
4msec
5
0~25
4msec
6
6~25
4msec
10
0~20
4msec
10
10~20
4msec
20
1~40
1 time
January 2007
6-79
Meaning
Initial value 1.5% (15) Maximum 5% (50), Minimum 0% (0), 0.1% increments Adjusts
only Top Speed for Feed Motor. Rewrites all data of 711-070 to 711-078 with specified
data.
Initial value 0% (0) Maximum 5% (50), Minimum 0% (0), 0.1% increments Adjusts
only Top Speed for Feed Motor. Rewrites all data of 711-080 to 711-088 with specified
data.
Initial value 3.6mm (172 pulse, 130 pulse for High Speed mode) +4.1mm/-2.1mm 10
pulse increments
Initial value 4.0mm (256 pulse) +4.1mm (346 pulse) / -2.3mm (206 pulse) 10 pulse
increments
0: High Speed mode Off 1: High Speed mode On
Initial value 31.1mm (450 pulse) +4.6mm (766 pulse) / -4.6mm (566 pulse) 10 pulse
increments
Correction value for [Size Detection Auto-Correction Function] Original Size Correc-
tion Value: +/-5mm
Initial value 0mm (0 pulse) +5.0mm (80 pulse) / -5.0mm (-80 pulse) 10 pulse incre-
ments This value also applies to Scan Position Transport Time.
Initial value 5.0mm (80 pulse) +4.4mm (150 pulse) / -4.4mm (10 pulse) 10 pulse
increments
Initial value 50.4mm (1080 pulse) +4.6mm (1180 pulse) / -4.6mm (980 pulse) 10
pulse increments
Initial value 14.6mm (224 pulse) +3.4mm (274 pulse) / -3.4mm (174 pulse) 10 pulse
increments
Initial value 15.0mm (241 pulse) +4.6mm (341 pulse) / -4.6mm (141 pulse) 10 pulse
increments
Initial value 0ms +80ms/-20ms, 4ms increments
Initial value 0m +88ms/-12ms, 4ms increments
Initial value 4ms +76ms/0ms, 4ms increments
Initial value 0ms +80ms/-20ms, 4ms increments
Initial value0ms +40ms/-20ms, 4ms increments
Initial value 0ms +80ms/-20ms, 4ms increments
Initial value 4ms +76ms/0ms, 4ms increments
Initial value 0ms +/-40ms, 4ms increments
Initial value0ms +40ms/-0ms, 4ms increments
Initial value 20 times +20 times/-19 times, 1 time increments