REP 22.4.3 Set Clamp Home Sensor
Parts List on PL 22.4
Removal
To avoid personal injury or shock, do not perform repair or adjustment with electrical
power applied to the machine.
Before turning OFF the power switch, note the following to prevent loss of customer data.
[with the FAX function]
Check that the "Job in Memory" lamp is off. Press the "Job Status" button and check that no job
is in progress.
[with the Printer function]
Check that "Ready to print/send" is displayed on the Control Panel.
1.
Remove the A-Finisher from the machine.
2.
Remove the Rear Cover. (PL 22.1)
3.
Disconnect the Connector. (Figure 1)
(1)Release Clamp and remove the wire.
(2)Disconnect Connector.
Figure 1 Disconnecting Connector (j0fa42221)
4.
Remove the Set Clamp Home Sensor Assembly. (Figure 2)
(1)Remove Screw.
(2)Remove Set Clamp Home Sensor Assembly.
Reversion 4.0
WorkCentre 7132
WARNING
CAUTION
Figure 2 Removing the Set Clamp Home Sensor Assembly (j0fa42222)
5.
Remove the Set Clamp Home Sensor. (Figure 3)
(1)Remove Set Clamp Home Sensor from Bracket.
(2)Disconnect Connector.
Figure 3 Removing the Set Clamp Home Sensor (j0fa42223)
Replacement
1.
Reverse the removal procedure for replacement.