Xerox WorkCentre 7132 Service Documentation page 1406

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Chain-Link Content
715-282
CCD Calib Y Scan Red
715-283
CCD Calib Y Scan Green
715-284
CCD Calib Y Scan Blue
715-285
CCD Calib M Scan Red
715-286
CCD Calib M Scan Green
715-287
CCD Calib M Scan Blue
715-288
CCD Calib C Scan Red
715-289
CCD Calib C Scan Green
715-290
CCD Calib C Scan Blue
715-291
CCD Calib PK Scan Red
715-292
CCD Calib PK Scan Green
715-293
CCD Calib PK Scan Blue
715-300
A6/Postcard Detection
715-302
A4S/8.5in Detection 2
715-303
B5/8x10 Detection
715-305
8.5x13/8.5x14 Detection
715-306
Original Detection Table for Special Paper
715-307
Original Size Detection Table Switch
715-308
5.5x8.5/Postcard Detection
715-310
A3/11x17 Detection
715-311
A4/8.5x11 Detection
715-312
A6S Threshold
715-344
Original Size Detection, Platen Background
Countermeasure for Dirt
715-345
GCO/TFX Size Switch
715-346
B4/8K Fast Scan Threshold Value Setting
715-347
8K/11x17SEF Fast Scan Threshold Value Setting 3
715-349
B6/5x7 Detection
715-362
FL_CHK_NG_Count
715-363
FL_CHK_NG_Data
715-418
AOCerr
715-550
BW Copy during AE
BGR-AE Adjustment Level (Text/Photo)
Reversion 4.0
WorkCentre 7132
Table 3 IISS
Default
Range
Meaning
0
0~1023
CCD Calib Y patch when reading Red (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib Y patch when reading Green (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib Y patch when reading Blue (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib M patch when reading Red (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib M patch when reading Green (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib M patch when reading Blue (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib C patch when reading Red (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib C patch when reading Green (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib C patch when reading Blue (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib PK patch when reading Red (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib PK patch when reading Green (Reflectivity LSB) "Factory Settings"
0
0~1023
CCD Calib PK patch when reading Blue (Reflectivity LSB) "Factory Settings"
0
0~2
0: Table default 1: A6SEF 2: PostcardSEF (mm series) or PostcardSEF (Inch series)
3
0~6
0: 210mm, 1: 211mm, 2: 212mm, 3: 213mm, 4: 214mm, 5: 215mm, 6: 216mm
0
0~3
0: Table default 1: B5LEF or ExecutiveLEF 2: 8x10LEF/8x10.5LEF 3: Off
0
0~3
0: Table default 1: 12.4inch 2: 13inch 3: 14inch
0
0~2
0: Do not use Special Table 1: APS OFF, A4; APS ON, A3 2: APS OFF, Letter; APS ON, 17inch
2
1~5
1: Inch13-2 2: mm-2 3: mm 4: Inch13-1 5: Inch14
0
0~2
0: Table default 1: A5SEF or 5.5x8.5SEF 2: PostCardLEF
0
0~3
0: Table default 1: A3SEF 2: 11x17SEF 3: A3SEF, 11x17SEF
0
0~3
0: Table default 1: A4LEF 2: 8.5x11LEF 3: 8.5x11LEF, A4LEF
90
50~110
Changes fast scan threshold for non-standard, Postcard SEF and A6SEF. If any value out of the
range of 50 to 110 is set up, fast scan threshold shall be 90mm.
50: 50mm or more; 110: 110mm (1mm/step)
0
0~1
0: Detection by 4 registers 1: Detection by 3 registers (countermeasure for dirt)
1
0~1
0: GCO (16K/8K=270x195/270x390) 1: TFX (16K/8K=267x194/267x388)
3
0~6
0: 256mm, 1: 258mm, 2: 260mm, 3: 262mm, 4: 264mm, 5: 266mm, 6: 268mm
0~6
0: 269mm, 1: 271mm, 2: 273mm, 3: 275mm, 4: 277mm, 5: 279mm, 6: 281mm
0
0~2
0: Table default 1: B6SEF 2: 5x7SEF
0
0~65535
Lamp Check NG Count (Reset when lamp is replaced)
0
0~1023
Data obtained when Lamp Check Fails (Read G Write data compared at checking)
0
0~255
No. of times the AOC flow has ended abnormally
0
0~4095
Value (0~15) x 3 = Erase Amount (8bit conversion)
(x12 for 10bit conversion)
Lower digits 0bit~3bit, Platen
4Bit~7Bit CVT or DADF machine
8Bit~11Bit CVT or DADF machine 2 Sided Copy
January 2007
6-83
General procedures information
IIT NVM List