Figure 3 Removing the Registration Unit
Replacement
NOTE: When reinstalling the Registration Unit, it might be necessary to rotate the Registration
Drive gears in order for the gears to be aligned properly.
Repairs/Adjustments
REP 2.4.1, REP 2.5.1
REP 2.5.1 Takeaway Roll
Parts List on PL 2.6
Removal
To avoid personal injury or shock, do not perform repair or adjustment with electrical
power applied to the machine.
Check that "Ready to Copy" is displayed on the Control Panel display.
1.
Switch off the power and disconnect the power cord.
2.
Remove the MSI Assembly. (REP 7.1.1)
3.
Remove the L/H Lower Cover.
4.
Remove the Chute. (Figure 1)
1.
Remove the screws (2).
2.
Release the hook.
3.
Remove the Chute.
January 2007
4-18
WARNING
CAUTION
Reversion 4.0
WorkCentre 7132