116-356 HDD Format RAP
HDD formatting failed.
Initial Actions
Power Off/On
Procedure
Check the connection of each ESS PWB connector. The connectors are correctly con-
nected.
Y
N
Connect the connectors.
Turn on the power again. The problem persists.
Y
N
Return to Service Call Procedures.
Check the HDD electrical connections (PL 11.2).
If the problem persists perform Hard Disk Diagnostic Program.
If the problem persists replace the HDD (PL 11.2).
Revision
WorkCentre 7132
116-357 PostScript RAP
An internal shutdown occurred after a processing error.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).