045-321 Marking Panel RAP
BSD-ON:6.2
There is an internal marking panel control error.
Procedure
Check the connectors and cables between the IIT/IPS PWB, CCD PWB, and the ESS PWB.
The connectors and cables are OK.
Y
N
Repair or replace as required (PL 13.3, PL 13.4, PL 11.2)
Power OFF and then ON. The problem continues.
Y
N
Rerun the job.
Replace the IIT/IPS PWB (PL 13.3). If the problem continues, replace the ROS (PL 3.1).
Status-indicator-raps
045-321, 045-322
045-322 Marking Pitch RAP
BSD-ON:6.4/6.5
There is an internal marking pitch control error.
Procedure
Check the connections and wiring between the MCU PWB and the ROS Unit. The
tions and wiring are OK.
Y
N
Repair replace as required (PL 11.1, PL 3.1).
Replace the ROS Unit (PL 3.1). If the problem continues, replace the MCU PWB (PL 11.1).