092-651 ADC Shutter Clean RAP
BSD-ON:9.4A
There is an ADC Sensor Voltage level failure.
Procedure
Remove the Sensor Bar Assembly (PL 11.1). Check the condition of the Sensor Bar Assem-
bly. The ADC Assembly is free of damage.
Y
N
Replace the Sensor Bar Assembly (PL 11.1).
Check the operating voltages between the ADC Sensor and the MCU PWB. The voltages are
correct.
Y
N
Replace the MCU PWB (PL 11.1).
Replace the Sensor Bar Assembly (PL 11.1).
Revision
WorkCentre 7132
092-661 Temperature Sensor RAP
BSD-ON:9.4A
There is a temperature sensor failure.
Procedure
Check the operating voltages between the Temperature/Humidity Sensor and the MCU PWB.
The voltages are correct.
Y
N
Verify that the circuit is not damaged. If no damage is found, replace the MCU PWB (PL
11.1).
Replace the Temperature/Humidity Sensor (PL 11.1).