Figure 4 Removing the Waste Auger drive shaft bushing
NOTE: In the next step, place a sheet of paper under the opening in the Waste Auger when
removing it from the frame.
9.
Remove the Waste Auger. (Figure 5)
Repairs/Adjustments
REP 4.2.2
2
Remove the Waste Auger
drive shaft bushing
January 2007
4-32
1
Remove the screws (3) and
remove the Waste Auger
Figure 5 Removing the Waste Auger
10. Open the left side door and position the levers (2) to the up or retract position. (Figure 6)