Avaya Nortel Communication Server 1000 Manual page 245

Ip line fundamentals
Hide thumbs Also See for Nortel Communication Server 1000:
Table of Contents

Advertisement

3
4
5
6
Incorrect configuration problems
TLAN network interface operation problems can arise from the standard I/O
filter connector in IPE modules on Large Systems. Some problem scenarios
and their respective solutions are outlined in
(page
Copyright © 2003–2008, Nortel Networks
.
Unscrew the existing filter connector from the I/O panel. There is
one screw on the lower front of the connector and one screw on the
upper back of the connector. Remove the connector.
Reposition the new NTCW84JA filter connector in the now vacant
I/O panel opening. See
I/O Panel filter connector for Large Systems" (page
Figure 49
NTCW84JA 50 pin ITG-specific I/O Panel filter connector for Large
Systems
Attach the new NTCW84JA ITG-specific filter connector to the I/O
panel by securely fastening the top back screw and the bottom front
screw.
Reconnect the NT8D81AA cable and secure it in place by snapping
shut the locking latches provided on the NTCW84JA connector.
246).
Nortel Communication Server 1000
IP Line Fundamentals
NN43100-500 02.02 Standard
Release 5.5 4 February 2008
Install the hardware components 245
Figure 49 "NTCW84JA 50 pin ITG-specific
—End—
Table 75 "I/O filter connector"
245).

Advertisement

Table of Contents
loading

Table of Contents