250 Installation and initial configuration of an IP Telephony node
To ensure proper connection, install the adapter securely; otherwise,
connectivity could be lost.
EMC Shielding Kit
An ITG EMC shielding kit (NTVQ83AA) must be installed on the ELAN
and TLAN network interface cables to meet regulatory requirements at the
installation site. As shown in
(page
interface CAT5 Ethernet cables during installation. Cable ties are then
placed to retain the ferrites in the correct position. This applies to Small
Systems and Large Systems.
Figure 52
ITG EMC Shielding Kit Deployment
Follow the steps in
Serial/ELAN/TLAN Adapter onto the Media Card" (page 250)
the ITG EMC shielding kit (NTVQ83AA) on the ELAN and TLAN network
interface cables.
Procedure 17
Installing the Shielded 50-pin to Serial/ELAN/TLAN Adapter onto the Media
Card
Step
1
2
Copyright © 2003–2008, Nortel Networks
.
250), a ferrite must be placed on both the ELAN and TLAN network
Procedure 17 "Installing the Shielded 50-pin to
Action
Install the Shielded 50-pin to Serial/ELAN/TLAN Adapter into the
card connector (1, 2, 3, or 4) where the Media Card is located.
Connect a shielded Cat 5 cable from the customer TLAN switch
equipment to the port labeled "TLAN".
Nortel Communication Server 1000
IP Line Fundamentals
NN43100-500 02.02 Standard
Release 5.5 4 February 2008
Figure 52 "ITG EMC Shielding Kit Deployment"