Replace The Nt8D81Ba Cable With The Nt8D1Aa Cable And Install The Ntcw84Jw Special Ipe Filter - Avaya Nortel Communication Server 1000 Manual

Ip line fundamentals
Hide thumbs Also See for Nortel Communication Server 1000:
Table of Contents

Advertisement

Replace the NT8D81BA cable with the NT8D1AA cable and install the NTCW84JW special IPE
Figure 110
NTAG81BA Maintenance Extender cable
Replace the NT8D81BA cable with the NT8D1AA cable and install
the NTCW84JW special IPE filter
This procedure explains how to replace the NT8D81BA cable with the
NT8D81AA cable and how to install the NTCW84JA special IPE filter in
the IPE module.
Cables are designated by the letter of the I/O panel cutout, such as A, B,
and C, where the 50-pin cable connector is attached. Each cable has three
20-pin connectors (16 positions are used), designated 1, 2, and 3, that
attach to the backplane. Using the designations described, the backplane
ends of the first cable are referred to as A-1, A-2, and A-3. The locations of
the cable connectors on the backplane are designated by the slot number
(L0 through L9 for NT8D11, L0 through L15 for NT8D37) and the shroud
row (1, 2, and 3). Using these designations, the slot positions in the first slot
are referred to as L0-1, L0-2, and L0-3.
In NT8D37BA and NT8D37EC (and later vintage) IPE Modules, all 16 IPE
card slots support 24-pair cable connections.
connections" (page 537)
to the inside of the I/O panel.
Table 152
NT8D37 cable connections
Copyright © 2003–2008, Nortel Networks
.
Backplane slots – shroud rows
L0–1, 2, 3
L1–1, 2, 3
L2–1, 2, 3
L3–1, 2, 3
L4–1, 2, 3
L5–1, 2, 3
L6–1, 2, 3
L7–1, 2, 3
L8–1, 2, 3
L9–1, 2, 3
L10–1, 2, 3
L11–1, 2, 3
Nortel Communication Server 1000
IP Line Fundamentals
NN43100-500 02.02 Standard
Release 5.5 4 February 2008
shows the cable connections from the backplane
I/O panel/cable designation
filter 537