AudioCodes Mediant 800B MSBR User Manual page 242

Multi-service business router; session border controller
Hide thumbs Also See for Mediant 800B MSBR:
Table of Contents

Advertisement

If an incoming call matches the characteristics of a routing rule, the device first runs the
assigned Call Setup Rules Set ID. The device uses the routing rule to route the call,
depending on the result of the Call Setup Rules Set ID:
Rule's condition is met: The device performs the rule's action and then runs the next
rule in the Set ID until the last rule or until a rule with an Exit Action Type. If the Exit
rule is configured with a "True" Action Value, the device uses the current routing rule.
If the Exit rule is configured with a "False" Action Value, the device moves to the next
routing rule. If an Exit Action Type is not configured and the device has run all the
rules in the Set ID, the default Action Value of the Set ID is "True" (i.e., use the current
routing rule).
Rule's condition is not met: The device runs the next rule in the Set ID. When the
device reaches the end of the Set ID and no Exit was performed, the Set ID ends with
a "True" result.
Note:
rules, they revert to their original values if the device moves to the next routing rule.
The following procedure describes how to configure Call Setup Rules in the Web interface.
You can also configure Call Setup Rules using the table ini file parameter, CallSetupRules
or CLI command, configure voip/services call-setup-rules.
To configure a Call Setup rule:
1.
Open the Call Setup Rules table (Configuration tab > VoIP menu > Services > Call
Setup Rules).
2.
Click Add; the following dialog box appears:
3.
Configure a Call Setup rule according to the parameters described in the table below.
4.
Click Submit, and then save ("burn") your settings to flash memory.
Table 19-12: Call Setup Rules Parameter Descriptions
Parameter
Index
[CallSetupRules_Index]
Rules Set ID
CLI: rules-set-id
User's Manual
If the source and/or destination numbers are manipulated by the Call Setup
Figure 19-27: Call Setup Rules Table - Add Record
Defines an index number for the new table record.
Note: Each rule must be configured with a unique index.
Defines a Set ID for the rule. You can define the same Set
ID for multiple rules to create a group of rules. You can
configure up to 10 Set IDs, where each Set ID can include
Description
242
Mediant 800B MSBR
Document #: LTRT-12813

Advertisement

Table of Contents
loading