AudioCodes Mediant 800B MSBR User Manual page 808

Multi-service business router; session border controller
Hide thumbs Also See for Mediant 800B MSBR:
Table of Contents

Advertisement

Parameter
Authentication per Port Table
Web: Authentication Table
EMS: SIP Endpoints >
Authentication
CLI: configure voip/gw analoggw
authentication
[Authentication]
Account Table
Web: Account Table
EMS: SIP Endpoints > Account
CLI: configure voip > sip-definition
account
[Account]
Proxy Registration Parameters
Web: Use Default Proxy
EMS: Proxy Used
CLI: enable-proxy
[IsProxyUsed]
User's Manual
This table parameter defines a user name and password for
authenticating each device port. The format of the ini file table
parameter is as follows:
[Authentication]
FORMAT Authentication_Index = Authentication_UserId,
Authentication_UserPassword, Authentication_Module,
Authentication_Port;
[\Authentication]
Where,
Module = Module number, where 1 denotes the module in
Slot 1
Port = Port number, where 1 denotes the Port 1 of the
module
For example:
Authentication 1 = lee,1552,1,2; (user name "lee" with
password 1552 for authenticating Port 2 of Module 1)
For a description o this table, see Configuring Authentication
on page 477.
Note: This parameter is applicable only to FXS and FXO
interfaces.
This table parameter configures the Account table for
registering and/or authenticating (digest) Trunk Groups or IP
Groups (e.g., an IP-PBX) to another Serving IP Group (e.g., an
Internet Telephony Service Provider - ITSP).
The format of the ini file table parameter is as follows:
[Account]
FORMAT Account_Index = Account_ServedTrunkGroup,
Account_ServedIPGroup, Account_ServingIPGroup,
Account_Username, Account_Password, Account_HostName,
Account_Register, Account_ContactUser,
Account_ApplicationType;
[\Account]
For a detailed description of this table, see ''Configuring
Registration Accounts'' on page 291.
Enables the use of Proxy Set ID 0 (for backward compatibility).
[0] No = (Default) Proxy Set 0 is not used.
[1] Yes = Proxy Set ID 0 is used.
Notes:
This parameter must be used only for backward
compatibility. If not required for backward compatibility,
make sure that this parameter is disabled, and use the
Proxy Set table for configuring all your Proxy Sets (except
for Proxy Set ID 0).
If you are not using a proxy server, you must configure
routing rules to route the call.
This parameter is applicable only to the Gateway
application.
808