Mediant 800B MSBR
Parameter
Web/EMS: TDM Bus Clock
Source
[TDMBusClockSource]
Web/EMS: TDM Bus Local
Reference
[TDMBusLocalReference]
Web/EMS: TDM Bus Enable
Fallback
[TDMBusEnableFallback]
Web: TDM Bus Fallback Clock
Source
EMS: TDM Bus Fallback Clock
[TDMBusFallbackClock]
Web/EMS: TDM Bus Net
Reference Speed
[TDMBusNetrefSpeed]
Web: TDM Bus PSTN Auto
FallBack Clock
EMS: TDM Bus Auto Fall Back
Enable
[TDMBusPSTNAutoClockEna
ble]
Web: TDM Bus PSTN Auto
Clock Reverting
EMS: TDM Bus Auto Fall Back
Reverting Enable
[TDMBusPSTNAutoClockRev
ertingEnable]
Version 6.8
with CAS protocols.
Defines the clock source to which the device synchronizes.
[1] Internal = (Default) Generate clock from local source.
[4] Network = Recover clock from PSTN line.
Note: For this parameter to take effect, a device reset is required.
Defines the physical Trunk ID from which the device recovers
(receives) its clock synchronization.
The range is 0 to the maximum number of Trunks. The default is 0.
Note: This parameter is applicable only if the parameter
TDMBusClockSource is set to 4 and the parameter
TDMBusPSTNAutoClockEnable is set to 0.
Defines the automatic fallback of the clock.
[0] Manual (default)
[1] Auto Non-Revertive
[2] Auto Revertive
Determines the fallback clock source on which the device
synchronizes in the event of a clock failure.
[4] Network (default)
[8] H.110_A
[9] H.110_B
[10] NetReference1
[11] NetReference2
Defines the NetRef frequency (for both generation and
synchronization).
[0] 8 kHz (default)
[1] 1.544 MHz
[2] 2.048 MHz
Enables the PSTN trunk Auto-Fallback Clock feature.
[0] Disable = (Default) Recovers the clock from the E1/T1 line
defined by the parameter TDMBusLocalReference.
[1] Enable = Recovers the clock from any connected
synchronized slave E1/T1 line. If this trunk loses its
synchronization, the device attempts to recover the clock from
the next trunk. Note that initially, the device attempts to recover
the clock from the trunk defined by the parameter
TDMBusLocalReference.
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only if the TDMBusClockSource
parameter is set to 4.
Enables the PSTN trunk Auto-Fallback Reverting feature. If
enabled and a trunk returning to service has an
AutoClockTrunkPriority parameter value that is higher than the
priority of the local reference trunk (set in the
TDMBusLocalReference parameter), the local reference reverts to
the trunk with the higher priority that has returned to service for the
device's clock source.
913
67. Configuration Parameters Reference
Description
Mediant 800B MSBR

Advertisement

Table of Contents
loading