57.10 Configuring Termination of Debug Capture Upon
Event
You can configure the device to stop a debug-traffic capture on the device's physical
network interfaces upon a user-defined event. This event can be a Syslog message or an
interface state-change. This feature supports all physical targets (TFTP, FTP, and USB),
and SSH retrieval, as well as regular and cyclic-buffer modes. When combined with cyclic-
buffer mode, this feature makes diagnosis of network problems easier.
To configure termination of debug capture upon a user-defined event or state change, use
the following CLI commands:
Defines the Syslog message event upon which the device stops the debug capture:
# debug capture data physical auto-stop event syslog
"<message>"
Defines a state change on a specific interface upon which the device stops the debug
capture:
# debug capture data physical auto-stop event state-change
<interface, e.g., GigabitEthernet 0/0>
Defines a state change on any interface upon which the device stops the debug
capture:
# debug capture data physical auto-stop event state-change any
Defines what to do with the debug capture when it is automatically stopped:
# debug capture data physical auto-stop [send <IP
address>|keep]
Where:
send - sends the capture to the defined IP address
keep - saves the capture on the device for later retrieval
Disables the automatic stopping feature for debug captures:
# no debug capture data physical auto-stop