Mediant 800B MSBR
Parameter
EMS: Data
[SerialData]
EMS: Parity
[SerialParity]
EMS: Stop
[SerialStop]
EMS: Flow Control
[SerialFlowControl]

67.1.8 Auxiliary and Configuration File Name Parameters

The configuration files (i.e., auxiliary files) can be loaded to the device using the Web
interface. For loading these files using the ini file, you need to configure these files in the ini
file and configured whether they must be stored in the non-volatile memory. The table
below lists the ini file parameters associated with these auxiliary files. For more information
on the auxiliary files, see ''Loading Auxiliary Files'' on page 599.
Table 67-8: Auxiliary and Configuration File Parameters
Parameter
General Parameters
[SetDefaultOnIniFileProcess] Determines if all the device's parameters are set to their defaults
[SaveConfiguration]
Auxiliary and Configuration File Name Parameters
Version 6.8
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 data bit.
[7] = 7-bit
[8] = (Default) 8-bit
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 polarity.
[0] = (Default) None
[1] = Odd
[2] = Even
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 stop bit.
[1] = (Default) 1-bit (default)
[2] = 2-bit
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 flow control.
[0] = (Default) None
[1] = Hardware
Note: For this parameter to take effect, a device reset is required.
before processing the updated ini file.
[0] = Disable - parameters not included in the downloaded ini file
are not returned to default settings (i.e., retain their current
settings).
[1] = Enable (default).
Note: This parameter is applicable only for automatic HTTP update
or Web ini file upload (not applicable if the ini file is loaded using
BootP).
Determines if the device's configuration (parameters and files) is
saved to flash (non-volatile memory).
[0] = Configuration isn't saved to flash memory.
[1] = (Default) Configuration is saved to flash memory.