Parameter
Web: Deny Authentication Timer
EMS: WEB Deny Authentication Timer
[DenyAuthenticationTimer]
Web: Display Login Information
[DisplayLoginInformation]
[EnableMgmtTwoFactorAuthentication] Enables Web login authentication using a third-party,
EMS: HTTPS Port
CLI: http-port
[HTTPport]
EMS: Disable WEB Config
[DisableWebConfig]
Version 6.8
67. Configuration Parameters Reference
Defines the duration (in seconds) for which login to the
Web interface is denied from a specific IP address (for all
users) when the number of failed login attempts has
exceeded the maximum. This maximum is defined by the
DenyAccessOnFailCount parameter. Only after this time
expires can users attempt to login from this same IP
address.
The valid value is 0 to 100000, where 0 means that login
is not denied regardless of number of failed login
attempts. The default is 60.
Enables display of user's login information on each
successful login attempt.
[0] = Disable (default)
[1] = Enable
smart card.
[0] = Disable (default)
[1] = Enable
When enabled, the device retrieves the Web user's login
username from the smart card, which is automatically
displayed (read-only) in the Web Login screen; the user
is then required to provide only the login password.
Typically, a TLS connection is established between the
smart card and the device's Web interface, and a
RADIUS server is implemented to authenticate the
password with the username. Thus, this feature
implements a two-factor authentication - what the user
has (the physical card) and what the user knows (i.e., the
login password).
Defines the LAN HTTP port for Web management
(default is 80). To enable Web management from the
LAN, configure the desired port.
Note: For this parameter to take effect, a device reset is
required.
Determines whether the entire Web interface is read-
only.
[0] = (Default) Enables modifications of parameters.
[1] = Web interface is read-only.
When in read-only mode, parameters can't be modified.
In addition, the following pages can't be accessed: 'Web
User Accounts', 'Certificates', 'Regional Settings',
'Maintenance Actions' and all file-loading pages ('Load
Auxiliary Files', 'Software Upgrade Wizard', and
'Configuration File').
Notes:
For this parameter to take effect, a device reset is
required.
765