Mediant 800B MSBR
Registrar server, using the "global" number in the From/To headers. If authentication
is necessary for registration, the device sends the user's username and password,
configured in the User Info table, in the SIP MD5 Authorization header.
You can configure up to 500 mapping rules in the GW User Info table. These rules can be
configured using any of the following methods:
Web interface - see ''Configuring GW User Info Table in Web Interface'' on page 615
CLI - see Configuring GW User Info Table in CLI on page 616
Loadable User Info file - see ''Configuring GW User Info Table in Loadable Text File''
on page 617
Notes:
To enable user registration, set the following parameters on the Proxy &
Registration page (Configuration tab > VoIP menu > SIP Definitions > Proxy &
Registration) as shown:
For FXS ports, when the device needs to send a new SIP request with the
Authorization header (e.g., after receiving a SIP 401 response), it uses the
username and password configured in the Authentication table (see Configuring
Authentication per Port on page 477). To use the username and password
configured in the User Info file, set the 'Password' parameter to any value other
than its default value.
46.1.5.2.1 Configuring GW User Info Table in Web Interface
The following procedure describes how to configure and register users in the GW User Info
table in the Web interface.
Note:
Info Table in Loadable Text File'' on page 617), all previously configured entries are
removed from the table in the Web interface and replaced with the entries from the
loaded User Info file.
To configure the GW User Info table in the Web interface:
1.
Open the GW User Info Table page (Configuration tab > VoIP menu > SIP
Definitions > User Information > GW User Info Table).
2.
Click Add: the following dialog box appears:
3.
Configure the GW User Info table parameters according to the table below.
Version 6.8
'Enable Registration': Enable (IsRegisterNeeded is set to 1).
'Registration Mode': Per Endpoint (AuthenticationMode is set to 0).
If a User Info file is loaded to the device (as described in ''Configuring GW User