Mediant 800B MSBR
67.2.10 Power over Ethernet Parameters
The power-over-Ethernet (PoE) parameters are described in the table below.
Parameter
Web: Power over Ethernet
Settings
CLI: configure system >
interface poe-table
[POETable]
67.3
Debugging and Diagnostics Parameters
This subsection describes the device's debugging and diagnostic parameters.
67.3.1 General Parameters
The general debugging and diagnostic parameters are described in the table below.
Table 67-20: General Debugging and Diagnostic Parameters
Parameter
CLI: enablesecsyslog
[EnableSecSyslog]
EMS: Enable Diagnostics
[EnableDiagnostics]
Version 6.8
Table 67-19: PoE Parameters
This table enables PoE (IEEE 802.3af-2003 and IEEE 802.3at) per LAN
port and configures the maximum power consumption allowed per port
for Class 0 clients connected to it.
[POETable]
FORMAT POETable_Index = POETable_PortEnable,
POETable_PortPower, POETable_PortATEnable;
[ \POETable ]
Where:
Index = Port number (where 0 is Port 1)
PortEnable = enables [1] or disables [0] IEEE 802.3af-2003 PoE
PortPower = defines maximum power consumption
PortATEnable = enables [1] or disables [0] IEEE 802.3at PoE
Note: For a description of this parameter, see ''Configuring Power over
Ethernet'' on page 125.
Enables the reporting of security-related events for the data-router
networking. When enabled, the data-router access list rules,
configured using the access-list CLI command, which are set to
"log", send Syslog messages whenever traffic matching the access
list is encountered.
[0] = (Default) Disabled
[1] = Enabled
Determines the method for verifying correct functioning of the
different hardware components on the device. On completion of the
check and if the test fails, the device sends information on the test
results of each hardware component to the Syslog server.
[0] = (Default) Rapid and Enhanced self-test mode.
[1] = Detailed self-test mode (full test of DSPs, PCM, Switch,
LAN, PHY and Flash).
[2] = A quicker version of the Detailed self-test mode (full test of
DSPs, PCM, Switch, LAN, PHY, but partial test of Flash).
Note: For this parameter to take effect, a device reset is required.
785
67. Configuration Parameters Reference
Description
Description
Mediant 800B MSBR