31.9

Configuring Call Waiting

The Call Waiting table lets you enable or disable call waiting per FXS port.
Notes:
You can enable or disable call waiting for all the device's ports using the global
parameter, 'Enable Call Waiting' in the Supplementary Services page
(Configuration tab > VoIP menu > GW and IP to IP > DTMF and
Supplementary > Supplementary Services).
The CPT file installed on the device must include a 'call waiting Ringback' tone
(caller side) and a 'call waiting' tone (called side, FXS interfaces only).
The EnableHold parameter must be enabled on both the calling and the called
sides.
For additional call waiting configuration, see the following parameters:
FirstCallWaitingToneID (in the CPT file), TimeBeforeWaitingIndication,
WaitingBeepDuration, TimeBetweenWaitingIndications, and
NumberOfWaitingIndications.
The following procedure describes how to configure call waiting per port in the Web
interface. You can also configure this using the table ini file parameter, CallWaitingPerPort
or CLI command, configure voip > gw analoggw call-waiting.
To enable call waiting per port:
1.
Open the Call Waiting page (Configuration tab > VoIP menu > GW and IP to IP >
Analog Gateway > Call Waiting).
2.
Click Add; the following dialog box appears:
3.
Configure call waiting per port according to the parameters described in the table
below.
4.
Click Submit, and then save ("burn") your settings to flash memory.
Table 31-6: Call Waiting Table Parameter Descriptions
Parameter
Index
[CallWaitingPerPort_Index]
Module
[CallWaitingPerPort_Module]
Port
[CallWaitingPerPort_Port]
Port Type
User's Manual
Figure 31-7: Call Waiting Table - Edit Record
Defines an index number for the new table record.
Note: Each table row must be configured with a unique index.
(Read-only) Displays the module number on which the port is
located.
(Read-only) Displays the port number.
(Read-only) Displays the port type (e.g., FXS).