67.1.7 Serial Parameters

The RS-232 serial parameters are described in the table below.
Parameter
[DisableRS232]
EMS: Baud Rate
[SerialBaudRate]
User's Manual
Defines the login password that the device uses for
authenticated access to the ACS.
The valid value is a string of up to 256 characters. By
default, no password is defined.
Defines the URL for the ACS connection request. For
example, http://10.31.4.115:82/tr069/.
Defines the connection request username used by the
ACS to connect to the device.
The valid value is a string of up to 256 characters. By
default, no username is defined.
Defines the connection request password used by the ACS
to connect to the device.
The valid value is a string of up to 256 characters. By
default, no password is defined.
Defines the inform interval (in seconds) at which the device
periodically communicates with the ACS. Each time the
device communicates with the ACS, the ACS sends a
response indicating whether or not the ACS has an action
to execute on the device.
The valid value is 0 to 4294967295. The default is 60.
Defines the minimum interval (in seconds) that the device
waits before attempting again to communicate with the
ACS after the previous communication attempt failure.
The valid value is 1 to 65535. The default is 5.
Defines the debug mode level, which is the type of
messages sent to the Syslog server.
The valid value is between 0 and 3, where 0 (default)
means no debug messages are sent and 3 is all message
types are sent.
Table 67-7: Serial Parameters
Enables the device's RS-232 (serial) port.
[0] = Enabled
[1] = (Default) Disabled
The RS-232 serial port can be used to change the networking
parameters and view error/notification messages. For how to establish a
serial communication with the device, refer to the Installation Manual.
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 baud rate.
The valid values include the following: 1200, 2400, 9600, 14400, 19200,
38400, 57600, or 115200 (default).
772
Mediant 800B MSBR
Description
Description
Document #: LTRT-12813