Mediant 800B MSBR
Parameter
Web: Analog Metering
Type
EMS: Metering Type
CLI: metering-type
[MeteringType]
Web: Analog TTX Voltage
Level
EMS: TTX Voltage Level
[AnalogTTXVoltageLevel ]
Charge Codes Table
Web: Charge Codes Table
EMS: Charge Codes
CLI: configure voip > gw
analoggw ChargeCode
[ChargeCode]
Version 6.8
file included in SIP INFO messages, which is always sent before 200
0K. The device ignores tariffs sent after the call is established.
[3] SIP RAW Data Provided = (Proprietary method of Cirpack)
Advice-of-Charge service toward the PSTN. The received AOC-D
messages contain a subtotal. When receiving AOC-D in raw format,
provided in the header of SIP INFO messages, the device parses
AOC-D raw data to obtain the number of units. This number is sent
in the Facility message with AOC-D. In addition, the device stores
the latest number of units in order to send them in AOC-E IE when
the call is disconnected).
[4] SIP RAW Data Incremental Provided = (Proprietary method of
Cirpack) Advice-of-Charge service toward the PSTN. The AOC-D
message in the payload is an increment. When receiving AOC-D in
raw format, provided in the header of SIP INFO messages, the
device parses AOC-D raw data to obtain the number of units. This
number is sent in the Facility message with AOC-D. The device
generates the AOC-E. Parsing every AOC-D received and summing
the values is required to obtain the total sum (that is placed in the
AOC-E).
Note: This parameter is applicable only to FXS interfaces and ISDN
Euro trunks for sending AOC Facility messages (see Advice of Charge
Services for Euro ISDN on page 468).
Determines the metering method for generating pulses (sinusoidal
metering burst frequency) by the FXS port.
[0] 12 KHz = (Default) 12 kHz sinusoidal bursts.
[1] 16 KHz = 16 kHz sinusoidal bursts.
[2] = Polarity Reversal pulses.
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
Determines the metering signal/pulse voltage level (TTX).
[0] 0V = 0 Vrms sinusoidal bursts.
[1] 0.5V = (Default) 0.5 Vrms sinusoidal bursts.
[2] 1V = 1 Vrms sinusoidal bursts
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
This table parameter configures metering tones and their time intervals
that the FXS interface generates to the Tel side or the E1 trunk (Euro
ISDN) sends in AOC Facility messages to the PSTN (i.e., PBX).
The format of the ini file table parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
955
67. Configuration Parameters Reference
Description
Mediant 800B MSBR

Advertisement

Table of Contents
loading

Table of Contents