Parameter
Web/EMS: MWI Display
CLI: enable-mwi
[MWIDisplay]
Web: Subscribe to MWI
EMS: Enable MWI Subscription
CLI: subscribe-to-mwi
[EnableMWISubscription]
Web: MWI Server IP Address
EMS: MWI Server IP
CLI: mwi-srvr-ip-addr
[MWIServerIP]
Web/EMS: MWI Server Transport
Type
CLI: mwi-srvr-transp-type
[MWIServerTransportType]
Web: MWI Subscribe Expiration
Time
EMS: MWI Expiration Time
CLI: mwi-subs-expr-time
[MWIExpirationTime]
Web: MWI Subscribe Retry Time
EMS: Subscribe Retry Time
CLI: mwi-subs-rtry-time
[SubscribeRetryTime]
Web: Subscription Mode
CLI: subscription-mode
[SubscriptionMode]
EMS: ETSI VMWI Type One
Standard
CLI: etsi-vmwi-type-one-standard
[ETSIVMWITypeOneStandard]
Version 6.8
Enables sending MWI information to the phone display.
[0] Disable = (Default) MWI information isn't sent to display.
[1] Enable = The device generates an MWI message
(determined by the parameter CallerIDType), which is
displayed on the MWI display.
Note:
This parameter is applicable only to FXS interfaces.
This parameter can also be configured in a Tel Profile.
Enables subscription to an MWI server.
[0] No (default)
[1] Yes
Notes:
To configure the MWI server address, use the MWIServerIP
parameter.
To configure whether the device subscribes per endpoint or
per the entire device, use the parameter SubscriptionMode.
Defines the MWI server's IP address. If provided, the device
subscribes to this IP address. The MWI server address can be
configured as a numerical IP address or as a domain name. If
not configured, the Proxy IP address is used instead.
Determines the transport layer used for outgoing SIP dialogs
initiated by the device to the MWI server.
[-1] Not Configured (default)
[0] UDP
[1] TCP
[2] TLS
Note: When set to 'Not Configured', the value of the parameter
SIPTransportType is used.
Defines the MWI subscription expiration time in seconds.
The default is 7200 seconds. The range is 10 to 2,000,000.
Defines the subscription retry time (in seconds) after last
subscription failure.
The default is 120 seconds. The range is 10 to 2,000,000.
Determines the method the device uses to subscribe to an MWI
server.
[0] Per Endpoint = (Default) Each endpoint subscribes
separately - typically used for FXS interfaces.
[1] Per Gateway = Single subscription for the entire device -
typically used for FXO interfaces.
Determines the ETSI Visual Message Waiting Indication
(VMWI) Type 1 sub-standard.
[0] = (Default) ETSI VMWI between rings
[1] = ETSI VMWI before ring DT_AS
[2] = ETSI VMWI before ring RP_AS