Setting The Communication With Gx Works2 - Mitsubishi Electric M800VS Series Connection And Set Up Manual

Hide thumbs Also See for M800VS Series:
Table of Contents

Advertisement

M800VS/M80V Series Connection and Setup Manual
20 Sequence Program Writing

20.4 Setting the Communication with GX Works2

20.4 Setting the Communication with GX Works2
To create the machine sequence and user safety sequence of the CNC, use the Mitsubishi Electric FA engineering software
GX Works2, which is the PLC development tool for the Mitsubishi PLC MELSEC Series.
Machine sequence: Control circuit created to control the machine tools (ladder circuit)
User safety sequence: Control circuit of the safety-related I/O observation created with the smart safety observation
function (ladder circuit)
(1) Start the setting screen by the following operation in the navigation window on GX Works2.
Select [Connection Destination], then double-click [Current Connection].
(2) Set the following items in the order of the list.
[For the machine sequence]
PC side I/F
Network No.
Station No.
Protocol
Sequencer side I/F
Type name
Station No.
IP address
IP Input Format
Station No. <-> IP information
Other Station Setting
Time out check (sec.)
Number of retries
Network Communication Route Detailed setting of Ethernet
Access to Ethernet module set on PCL side I/F
(*1) Double-click [Ethernet Board] to display the setting item.
(*2) Double-click [Ethernet Module] to display the setting item.
(*3) Double-click [Other Station (Single network)] to display the setting item.
(*4) Double-click [Ethernet] to display the setting item.
[Transfer Setup Connection screen]
Setting item
Setting content
Ethernet board
1
1
TCP
Ethernet unit
QJ71E71
1
IP address of CNC
DEC.
Automatic Response System
Other station (Single network)
Arbitrary time (Approx. 10 sec. or more)
0
425
Remark
(*1)
(*1)
(*1)
(*2)
(*2)
(*2)
(*2)
(*2)
(*3)
(*3)
(*4)
IB-1501613-A