weight of queue 3: 1
Table 1-2 Description on the fields of the display qos-interface all command
line-rate
Inbound
1024 Kbps
Queue scheduling mode
weight of queue 0

display qos-interface line-rate

Syntax
display qos-interface { interface-type interface-number | unit-id } line-rate
View
Any view
Parameter
interface-type interface-number: Specifies the type and number of a port, for which the line rate
configuration information is to be displayed.
unit-id: Unit ID, which is fixed to 1. With this argument specified, the rate limiting configuration of all the
ports on the device is displayed.
Description
Use the display qos-interface line-rate command to display the rate limiting configuration of a port or
all the ports on the device.
Related command: line-rate.
Example
# Display the rate limiting configuration of Ethernet 1/0/1.
<Sysname> display qos-interface Ethernet 1/0/1 line-rate
Ethernet1/0/1: line-rate
Inbound: 128 Kbps
Refer to
Table 1-2
display qos-interface mirrored-to
Syntax
display qos-interface { interface-type interface-number | unit-id } mirrored-to
Field
for the description on the output fields.
Description
Port with rate limiting configured
Inbound direction. That is, rate limiting is performed to the
inbound packets
The target rate
Queue scheduling algorithm adopted
Scheduling weight for queue 0