System-Guard Timer-Interval - H3C s3100 series Command Manual

Hide thumbs Also See for s3100 series:
Table of Contents

Advertisement

Example
# Apply the system-guard function to Ethernet1/0/1 through Ethernet1/0/10 ports.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] system-guard permit Ethernet 1/0/1 to Ethernet 1/0/10

system-guard timer-interval

Syntax
system-guard timer-interval isolate-timer
undo system-guard timer-interval
View
System view
Parameter
isolate-timer: Length of the isolation after an attack is detected, in the range of 1 to 10,000 in minutes.
Description
Use the system-guard timer-interval command to set the length of the isolation after an attack is
detected.
Use the undo system-guard timer-interval command to restore the length of the isolation to the
default value.
By default, the length of the isolation after an attack is detected is 10 minutes.
Related command: display system-guard state.
Example
# Set the length of the isolation after an attack is detected to 20 minutes.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname]system-guard timer-interval 20