Info-Center Timestamp - H3C s3100 series Command Manual

Hide thumbs Also See for s3100 series:
Table of Contents

Advertisement

Parameter
None
Description
Use the info-center synchronous command to enable synchronous information output, so that if
system information (such as log information) is output when the user is inputting information, the
command prompt and the input information are echoed after the output (note that, the command prompt
is echoed in command edit state but is not echoed in interactive state).
Use the undo info-center synchronous command to disable synchronous information output.
By default, the synchronous information output function is disabled.
The synchronous information output function is used in the case that your input is interrupted by a
large amount of system output. With this function enabled, the system echoes your previous input
and you can continue your operations from where you were stopped.
Running the info-center synchronous command during debugging information collection may
result in a command prompt echoed after each item of debugging information. To avoid
unnecessary output, it is recommended to disable synchronous information output in such case.
Example
# Enable synchronous information output.
<Sysname>
system-view
System View: return to User View with Ctrl+Z.
[Sysname]info-center synchronous
Current IC terminal output sync is on

info-center timestamp

Syntax
info-center timestamp { log | trap | debugging } { boot | date | none }
undo info-center timestamp { log | trap | debugging }
View
System view
Parameter
log: Specifies log information.
trap: Specifies trap information.
debugging: Specifies debugging information.
boot: Specifies to adopt the time elapsed since system boot, which is in the format of "xxxxxx.yyyyyy",
where xxxxxx is the high 32 bits and yyyyyy the low 32 bits of the elapsed milliseconds.
1-14