Garp Timer Leaveall - H3C s3100 series Command Manual

Hide thumbs Also See for s3100 series:
Table of Contents

Advertisement

Timer
Leave
LeaveAll
In networking, the following GARP timer settings are recommended:
GARP hold timer: 100 centiseconds (1 second)
GARP Join timer: 600 centiseconds (6 seconds)
GARP Leave timer: 3000 centiseconds (30 seconds)
Related commands: display garp timer.
Examples
# Set the GARP Join timer to 30 centiseconds for Ethernet1/0/1.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface Ethernet 1/0/1
[Sysname-Ethernet1/0/1] garp timer join 30

garp timer leaveall

Syntax
garp timer leaveall timer-value
undo garp timer leaveall
View
System view
Parameters
timer-value: Setting (in centiseconds) of the GARP LeaveAll timer. You need to set this argument with
the Leave timer settings of other Ethernet ports as references. That is, this argument needs to be larger
than the Leave timer settings of any Ethernet ports. Also note that this argument needs to be a multiple
of 5 and cannot be larger than 32,765.
Description
Use the garp timer leaveall command to set the GARP LeaveAll timer.
Use the undo garp timer leaveall command to restore the default setting of the GARP LeaveAll timer.
Lower threshold
This lower threshold is greater than
twice the timeout time of the Join
timer. You can change the threshold
by changing the timeout time of the
Join timer.
This lower threshold is greater than
the timeout time of the Leave timer.
You can change threshold by
changing the timeout time of the
Leave timer.
This upper threshold is less than the
timeout time of the LeaveAll timer. You
can change the threshold by changing
the timeout time of the LeaveAll timer.
32,765 centiseconds