Garp Timer - H3C s3100 series Command Manual

Hide thumbs Also See for s3100 series:
Table of Contents

Advertisement

garp timer

Syntax
garp timer { hold | join | leave } timer-value
undo garp timer { hold | join | leave }
View
Ethernet port view
Parameters
hold: Sets the GARP Hold timer.
join: Sets the GARP Join timer.
leave: Sets the GARP Leave timer.
timer-value: Timeout time (in centiseconds) of the GARP timer (Hold, Join or Leave) to be set.
Description
Use the garp timer command to set a GARP timer (that is, the Hold timer, the Join timer, or the Leaver
timer) for an Ethernet port.
Use the undo garp timer command to restore the default setting of a GARP timer.
By default, the Hold, Join, and Leave timers are set to 10, 20, and 60 centiseconds.
Note that:
The setting of each timer must be a multiple of 5 (in centiseconds).
The timeout ranges of the timers vary depending on the timeout values you set for other timers. If
you want to set the timeout time of a timer to a value out of the current range, you can set the
timeout time of the associated timer to another value to change the timeout range of this timer.
The following table describes the relations between the timers:
Table 1-2 Relations between the timers
Timer
Hold
Join
Garp Leave Time
Garp LeaveAll Time
Garp Hold Time
Lower threshold
10 centiseconds
This lower threshold is greater than
or equal to twice the timeout time of
the Hold timer. You can change the
threshold by changing the timeout
time of the Hold timer.
: 60 centiseconds
: 1000 centiseconds
: 10 centiseconds
This upper threshold is less than or equal
to one-half of the timeout time of the Join
timer. You can change the threshold by
changing the timeout time of the Join
timer.
This upper threshold is less than one-half
of the timeout time of the Leave timer.
You can change the threshold by
changing the timeout time of the Leave
timer.
1-3
Upper threshold

Hide quick links:

Advertisement

Table of Contents