Display Transceiver Alarm Interface - H3C s3100 series Command Manual

Hide thumbs Also See for s3100 series:
Table of Contents

Advertisement

Parameter
None
Description
Use the display schedule reboot command to display information about scheduled reboot.
Related command: schedule reboot at, schedule reboot delay.
Example
# Display the information about scheduled reboot.
<Sysname> display schedule reboot
System will reboot at 16:00:00 2002/11/1 (in 2 hours and 5 minutes).

display transceiver alarm interface

Syntax
display transceiver alarm interface [ interface-type interface-number ]
View
Any view
Parameters
interface-type interface-number: Interface type and interface number.
Description
Use the display transceiver alarm interface command to display the current alarm information of a
single or all transceivers.
If no error occurs, None is displayed.
Table 3-5
shows the alarm information that may occur for the four types of transceivers.
Table 3-5 Description on the fields of display transceiver alarm interface
GBIC/SFP
RX loss of signal
RX power high
RX power low
TX fault
TX bias high
TX bias low
TX power high
TX power low
Temp high
Temp low
Field
Remarks
RX signal is lost.
RX power is high.
RX power is low.
TX fault
TX bias current is high.
TX bias current is low.
TX power is high.
TX power is low.
Temperature is high.
Temperature is low.
3-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents