TRCE-1006
Message
<timestamp>, [TRCE-1006], <sequence-number>,, INFO, <system-name>, FTP
Connectivity Test succeeded to FTP site '
'.
Probable Cause
Indicates that a connectivity test to the FTP host has succeeded. This feature is enabled by the
supportFtp -t command.
Recommended
No action is required.
Action
Severity
INFO
TRCE-1007
Message
<timestamp>, [TRCE-1007], <sequence-number>,, ERROR, <system-name>, Notification
of this CP has failed. Parameters temporarily out of synch with other CP.
Probable Cause
Indicates that the active CP is unable to alert the standby CP of a change in trace status. This
message is only applicable to the Brocade 24000, and 48000.
Recommended
This message is often transitory. Wait a few minutes and try the command again.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
TRCE-1008
Message
<timestamp>, [TRCE-1008], <sequence-number>, FFDC, CRITICAL, <system-name>,
Unable to load trace parameters.
Probable Cause
Indicates that the active CP is unable to read stored trace parameters.
Recommended
Reboot the CP (dual-CP system) or restart the switch.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL
Fabric OS Message Reference
53-1000437-01
TRCE-1006
<FTP target configured by users.>
70
423