27
FW-1118
FW-1118
Message
<timestamp>, [FW-1118], <sequence-number>,, INFO, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the number of fabric reconfigurations has fallen below the low boundary. The
following occurrences can cause a fabric reconfiguration:
•
•
•
•
A low number of fabric reconfigurations means that the fabric is functioning normally.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation.
Severity
INFO
FW-1119
Message
<timestamp>, [FW-1119], <sequence-number>,, INFO, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the number of fabric reconfigurations has risen above the high boundary. The
following occurrences can cause a fabric reconfiguration:
•
•
•
•
Recommended
Verify that all interswitch link (ISL) cables are properly connected at both ends. Verify that the small
Action
form-factor pluggable (SFP) has not become faulty. An inexplicable fabric reconfiguration might be
a transient error and might not require troubleshooting.
Severity
INFO
168
Two switches with the same domain ID have connected to one another.
Two fabrics have joined.
An E_Port has gone offline.
A principal link has segmented from the fabric.
Two switches with the same domain ID have connected to one another.
Two fabrics have joined.
An E_Port has gone offline.
A principal link has segmented from the fabric.
Fabric OS Message Reference
53-1000437-01