ZONE-1018

ZONE-1018
Message
<timestamp>, [ZONE-1018], <sequence-number>,, ERROR, <system-name>, Incorrect
zoning enforcement type(<zone type>) at port(<port number>).
Probable Cause
Indicates that an incorrect zoning enforcement type was reported on the specified port. This is a
software error. A QuickLoop zone type (value = 4) or an uninitialized type (value = 0) are invalid.
The valid zone type values are:
QuickLoop zones are not supported in Fabric OS v4.x and above.
Recommended
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
Action
supportSave command and contact your switch service provider.
Severity
ERROR

ZONE-1019

Message
<timestamp>, [ZONE-1019], <sequence-number>,, ERROR, <system-name>, Transaction
Commit failed. Reason code <reason code> (<Application reason>) - \"<reason
string>\"
Probable Cause
Indicates that the reliable commit service (RCS) had a transmit error. RCS is a protocol used to
transmit changes to the configuration database within a fabric.
Recommended
Often this message indicates a transitory problem. Wait a few minutes and retry the command.
Action
Make sure that your changes to the zone database are not overwriting the work of another admin.
Run the cfgTransShow command to find out if there is any outstanding transaction running on the
local switches.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.