27
FW-1003
FW-1003
Message
<timestamp>, [FW-1003], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the internal temperature of the switch has risen above the high boundary to a value
that might damage the switch.
Recommended
This message generally appears when a fan fails. If so, a fan-failure message accompanies this
Action
message. Replace the fan field-replaceable unit (FRU).
Severity
WARNING
FW-1004
Message
<timestamp>, [FW-1004], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause
Indicates that the internal temperature of the switch has changed from a value outside of the
acceptable range to a value within the acceptable range.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation. If you receive a temperature-related message, check for an accompanying
fan-related message and check fan performance. If all fans are functioning normally, check the
climate control in your lab.
Severity
INFO
FW-1005
Message
<timestamp>, [FW-1005], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause
Indicates that the speed of the fan has changed. Fan problems typically contribute to temperature
problems.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation. Consistently abnormal fan speeds generally indicate that the fan is
malfunctioning.
Severity
INFO
156
Fabric OS Message Reference
53-1000437-01