SEC-1051

SEC-1051
Message
<timestamp>, [SEC-1051], <sequence-number>,, ERROR, <system-name>, Missing brace
for port list
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR

SEC-1052

Message
<timestamp>, [SEC-1052], <sequence-number>,, ERROR, <system-name>, Invalid input.
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR

SEC-1053

Message
<timestamp>, [SEC-1053], <sequence-number>,, ERROR, <system-name>, Invalid pFCS
list
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR
346
<port list>
<pFCS list>
.
Fabric OS Message Reference
53-1000437-01